Additional Information | : | 2-Port |
Amperage Rating | : | 6.8/8.3 A |
Compressor Type | : | Inverter Twin BLDC Rotary |
Cooling BTU Rating | : | 18000 Btu/hr |
Cooling Operating Temperature | : | 14 to 114.8 deg F |
Cooling Sound Level | : | 48 dBA |
EER Rating | : | 12.7 |
Finish | : | Galvanized/Powder-Coated |
Frequency Rating | : | 60 Hz |
HSPF Rating | : | 10 |
Heating BTU Rating | : | 22000 Btu/hr |
Heating CFM Rating | : | 1667 cfm |
Heating Operating Temperature | : | 5 to 75 deg F |
Heating Sound Level | : | 51 dBA |
Liquid Line Size | : | 1/4 in |
Material | : | Steel |
Overall Height | : | 31-7/16 in |
Overall Length | : | 12-3/16 in |
Overall Width | : | 34-5/8 in |
Phase | : | 1 ph |
Refrigerant Type | : | R-410A |
SEER Rating | : | 19.5 |
Series | : | FJM Series |
Suction Line Size | : | 3/8 in, 1/2 in |
Suitable For Use With | : | AR TSFABWKNCV, AR BSFCMWKNCV, AR TSFYBWKNCV, AC0 BNNDCH/AA and AC0 BN1DCH/AA Evaporators |
Voltage Rating | : | 208/230 V |
This multi-zone residential and light commercial system offers three different indoor units to choose from and multiple control options. With minimal installation space, it's a flexible option for homes or offices with many rooms. The Free Joint Multi (FJM) unit supports 2 to 5 indoor units for multi-zone control with one outdoor unit.
Samsung Heat Pump Condensing Unit, Series: FJM Series, 208/230 V, 6.8/8.3 A, 60 Hz, 1 ph Phase, 22000 Btu/hr Heating, 18000 Btu/hr Cooling, 1667 cfm Heating CFM Rating, 12.7 EER Rating, 19.5 SEER, 10 HSPF, Inverter Twin BLDC Rotary Compressor, R-410A Refrigerant, 1/4 in Liquid Line, 3/8 in, 1/2 in Suction Line, 51 dBA Heating Sound Level, 48 dBA Cooling Sound Level, Steel, Finish: Galvanized/Powder-Coated, 5 to 75 deg F Heating Operating Temperature, 14 to 114.8 deg F Cooling Operating Temperature, 12-3/16 in Overall Length, 34-5/8 in Overall Width, 31-7/16 in Overall Height, For Use With: AR TSFABWKNCV, AR BSFCMWKNCV, AR TSFYBWKNCV, AC0 BNNDCH/AA and AC0 BN1DCH/AA Evaporators, Additional Information: 2-Port
- Auto or manual addressing of indoor units
- The outdoor unit shall supply power individually to the indoor units via 14 AWG X 3 power wire
- Soft-start to reduce current demand during compressor start
- Auto-restart after power loss
- System can be set up as heating/cooling, cooling only, or heating only via outdoor unit option setting
- Available maximum current setting option to reduce maximum operating current
- System energy consumption can be viewed using Samsung SmartThings mobile app (not revenue grade, for reference only)
- The outdoorunit shall be galvanized steel with a baked on powder coated finish for durability
- The heat exchanger shall be mechanically bonded fin to copper tube
- Control signal shall be a DDC type signal
- Interconnect control wire between outdoor and indoor units shall be 16AWG X 2
- The system shall integrate with the Samsung Controls Solution without the use of an interface module
- The refrigerant shall be R410A
- The compressor shall be hermetically sealed, inverter controlled, Twin BLDC Rotary
- Refrigerant flow shall be controlled by 2 separate electronic expansion valves at outdoor unit