Samsung SAMCNH18LDB

Samsung AC018BNLDCH/AA Slim Duct Indoor Unit, 208 to 230 V, 20.1 A, 18000 Btu/hr Cooling, 20000 Btu/hr Heating BTU, 1 ph

Manufacturer: Samsung
Part #: SAMCNH18LDB
Customer Part #:
Login for Availability
Login for Price
Additional Information      :      Single Zone
Amperage Rating      :      20.1 A
BTU Rating      :      18000 Btu/hr Cooling, 20000 Btu/hr Heating
CFM Rating      :      2154 cfm Condenser, 600 cfm Evaporator
Compressor Type      :      Twin BLDC Rotary
Drive Type      :      Inverter
EER Rating      :      12.1
Finish      :      Galvanized
Frequency Rating      :      60 Hz
HSPF Rating      :      7.5
Material      :      Steel
Number of Fan Speeds      :      3
Overall Height      :      7-13/16 in
Overall Length      :      17-5/16 in
Overall Width      :      43-5/16 in
Phase      :      1 ph
Power Rating      :      125 W, 84 W
Refrigerant Type      :      R-410A
SEER Rating      :      20
Sound Level      :      35 dBA
Temperature Rating      :      64 to 90 deg F Cooling, <=86 deg F Heating
Voltage Rating      :      208 to 230 V

At only 7-7/8 in thick, the slim duct makes installation, maintenance and repair hassle-free. Its lightweight chassis also makes installation easier than ever. The slim duct unit includes a built-in condensate pump as standard.

Samsung Slim Duct Indoor Unit, 208 to 230 V, 20.1 A, 125 W, 84 W, 60 Hz, 1 ph, 3 Number of Fan Speeds, 18000 Btu/hr Cooling, 20000 Btu/hr Heating, 2154 cfm Condenser, 600 cfm Evaporator CFM Rating, 12.1 EER, 20 SEER, HSPF: 7.5, Twin BLDC Rotary Compressor, R-410A, Inverter Drive, 35 dBA, Steel, Galvanized, 64 to 90 deg F Cooling, <=86 deg F Heating, 17-5/16 in Overall Length, 43-5/16 in Overall Width, 7-13/16 in Overall Height, Additional Information: Single Zone

  • The outdoor unit shall supply power to indoor unit via 14/3 AWG power wire
  • High voltage terminal block temperature sensor to disable unit in the event of power connection overheating
  • Integral condensate pump with maximum 29 in lift from bottom of the unit with check valve and float switch that disables indoor should condensate overflow be detected
  • Auto restart after power loss
  • Soft start compressor minimizing current inrush
  • All heat exchangers shall be mechanically bonded aluminum fin to copper tube
  • The condensing unit heat exchanger salt spray test method ISO 9227 the heat exchanger showed no unusual rust or corrosion development to 3000 hr
  • Base pan heater equipped as standard
  • Instruction/Installation Manual https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_AC018BNLDCH_AA_Instruction_Installation_Manual.pdf
  • Owners/User Manual https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_AC018BNLDCH_AA_Owners_User_Manual.pdf
  • Service Manual https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_AC018BNLDCH_AA_Service_Manual.pdf
  • Specification Sheet https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_AC018BNLDCH_AA_Specification_Sheet.pdf