Additional Information | : | 1/4 in, 3/8 in Connection, Slim Duct Single-Zone Duct |
Amperage Rating | : | 10.9 A |
BTU Rating | : | 12000 Btu/hr, 14000 Btu/hr |
CFM Rating | : | 300 cfm, 353 cfm, 399 cfm |
Compressor Type | : | Twin BLDC Rotary |
Drive Type | : | Inverter |
EER Rating | : | 11.5 |
Finish | : | Galvanized |
Frequency Rating | : | 60 Hz |
Fuse Rating | : | 15 A |
HSPF Rating | : | 9.2 |
Material | : | Steel |
Number of Fan Speeds | : | 3 |
Overall Height | : | 7-13/16 in |
Overall Length | : | 17-5/16 in |
Overall Width | : | 35-7/16 in |
Phase | : | 1 ph |
Power Rating | : | 84 W |
Refrigerant Type | : | R-410A |
SEER Rating | : | 19 |
Sound Level | : | 27 dBA, 31 dBA, 34 dBA |
Temperature Rating | : | 63 to 90 deg F, <=86 deg F |
Voltage Rating | : | 208-230 V |
At only 7-7/8 in THK, the slim duct makes installation, maintenance and repair hassle-free. Its lightweight chassis also makes installation easier than ever. The slim duct unit includes a built-in condensate pump as standard.
Samsung Split System Unit, 208-230 V, 10.9 A, 84 W, 60 Hz, 1 ph, 3 Number of Fan Speeds, 12000 Btu/hr, 14000 Btu/hr, 300 cfm, 353 cfm, 399 cfm CFM Rating, 11.5 EER, 19 SEER, HSPF: 9.2, Twin BLDC Rotary Compressor, R-410A, 15 A Fuse, Inverter Drive, 27 dBA, 31 dBA, 34 dBA, Steel, Galvanized, 63 to 90 deg F, <=86 deg F, 17-5/16 in Overall Length, 35-7/16 in Overall Width, 7-13/16 in Overall Height, Additional Information: 1/4 in, 3/8 in Connection, Slim Duct Single-Zone Duct
- The outdoor unit shall supply power to indoor unit via 14 AWG x 3 power wire
- High voltage terminal block temperature sensor to disable unit in the event of power connection overheating
- Integral condensate pump with maximum 29 in lift from bottom of the unit with check valve and float switch that disables indoor should condensate overflow be detected
- Auto-restart after power loss
- Soft start compressor minimizing current inrush
- All heat exchangers shall be mechanically bonded aluminum fin to copper tube
- The condensing unit heat exchanger salt spray test method ISO 9227 the heat exchanger showed no unusual rust or corrosion development to 500 hr
- Base pan heater equipped as standard indoor fan is sirocco-type
- Three-fan speed settings and auto setting
- Washable filter as standard
- Control wiring shall be two 16 AWG
- No additional interface modules/adapters are required when connecting to Samsung central control options
- The unit shall be operated via a wireless or wired remote control with DDC type signal
- Dual-set temperature support when connected to MWR-WG00UN advanced wired controller or central control options
- Wired or wireless controllers must be purchased separately
- The compressor shall be hermetically sealed, inverter controlled BLDC rotary type
- Refrigerant flow shall be controlled by an electronic expansion valve at outdoor unit