Samsung SAMUCNH09NDB

Samsung AC009BNNDCH/AA Mini-Split Heat Pump Indoor Unit, 208 to 230 V, 10.9 A, 1 ph -Phase, HIPS

Manufacturer: Samsung
Part #: SAMUCNH09NDB
Customer Part #:
Login for Availability
Login for Price
Additional Information      :      Twin BLDC Rotary Compressor, Single Zone
Amperage Rating      :      10.9 A
BTU Rating      :      9100 Btu/hr Cooling, 10000 Btu/hr Heating
CFM Rating      :      1060 cfm Condenser, 283 cfm Evaporator
Drive Type      :      Inverter
EER Rating      :      13
Frequency Rating      :      60 Hz
HSPF Rating      :      9.5
Material      :      HIPS
Mounting Type      :      Cassette
Overall Height      :      9-13/16 in
Overall Length      :      22-5/8 in
Overall Width      :      22-5/8 in
Phase      :      1 ph
Power Rating      :      40 W Condenser, 65 W Evaporator
Refrigerant Type      :      R-410A
SEER Rating      :      22
Sound Level      :      31 dBA
Temperature Rating      :      61 to 90 deg F Cooling, <=86 deg F Heating
Voltage Rating      :      208 to 230 V

Samsung WindFree™ mini four-way cassette uses thousands of micro holes to distribute air throughout the space without blowing directly on the occupants. You can activate WindFree™ cooling by pressing the WindFree™ button on the controller.

Samsung Mini-Split Heat Pump Indoor Unit, 208 to 230 V, 10.9 A, 40 W Condenser, 65 W Evaporator, 60 Hz, 1 ph, 9100 Btu/hr Cooling, 10000 Btu/hr Heating, 1060 cfm Condenser, 283 cfm Evaporator CFM Rating, 13 EER, 22 SEER, HSPF: 9.5, R-410A, Inverter Drive, 31 dBA, Cassette Mount, HIPS, 61 to 90 deg F Cooling, <=86 deg F Heating, 22-5/8 in Overall Length, 22-5/8 in Overall Width, 9-13/16 in Overall Height, Additional Information: Twin BLDC Rotary Compressor, Single Zone

  • The indoor unit shall feature WindFree™ mode, in cooling mode, as room temperature nears set temperature, the unit will close its louver and will disperse air into the space through thousands of micro holes on the front of the indoor unit preventing cold air drafts on occupants
  • The outdoor unit shall supply power to indoor unit via 14/3 AWG power wire
  • High voltage terminal block temperature sensor to disable unit in the event of power connection overheating
  • Auto restart after power loss
  • Soft start compressor minimizing current inrush
  • Base pan heater equipped as standard
  • All heat exchangers shall be mechanically bonded aluminum fin to copper tube
  • The condensing unit heat exchanger salt spray test method ASTMB117-18 the heat exchanger showed no unusual rust or corrosion development to 500 hr
  • Integral condensate pump with maximum 29 in lift from bottom of the unit with check valve and float switch to disable unit in the event of condensate overflow
  • Knock-out for outside air capability (with booster fan connection)
  • Instruction/Installation Manual https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_AC009BNNDCH_AA_Instruction_Installation_Manual.pdf
  • Owners/User Manual https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_AC009BNNDCH_AA_Owners_User_Manual.pdf
  • Service Manual https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_AC009BN1DCH_AA_Service_Manual.pdf
  • Submittal https://assets.unilogcorp.com/267/ITEM/DOC/Samsung_AC009BNNDCH_AA_Submittal.pdf