KeepRite® HEHG9MVE0401410

KeepRite® G9MVE0401410A Gas Furnace, 40000 Btu/hr Input BTU, 115 VAC, 1000 cu-ft/min, 1/2 hp, 96% AFUE, Multi-Position

Manufacturer: Carrier
Part #: HEHG9MVE0401410
Customer Part #:
Login for Availability
Login for Price
AFUE Rating      :      96 %
Amperage Rating      :      7.5 A
Blower Size      :      11 in Dia x 7 in W
CFM Rating      :      1000 cfm
Cabinet Dimensions      :      14-3/16 in W x 29-1/2 in D x 35 in H
Configuration      :      Multi-Position
Connection Type      :      1/2 in NPT
Frequency Rating      :      60 Hz
Fuel Type      :      Natural Gas
HP Rating      :      1/2 hp
Input BTU Rating      :      40000 Btu/hr
Material      :      Steel
Model      :      G9MVE
Number of Burners      :      2
Phase      :      1 ph
Rotational Speed      :      400 to 1200 rpm
Temperature Rise      :      30 - 60 deg F Low, 40 - 70 deg F High
Tonnage      :      2 ton at 400 cfm, 2.5 ton at 350 cfm
Transformer Rating      :      40 VA at 24 VAC
Voltage Rating      :      115 VAC

KeepRite® Gas Furnace, G9MVE Model, 40000 Btu/hr Input BTU Rating, 115 VAC, 7.5 A, 1000 cu-ft/min, 1/2 hp, 96% AFUE, 1 -Phase, 60 Hz, Configuration: Multi-Position, 1/2 in NPT Connection, Natural Gas Fuel, 2 -Burner, 7 in W x 11 in Dia Blower Size, 14-3/16 in W x 35 in H x 29-1/2 in D Cabinet Dimensions, 400 - 1200 rev/min, 2 ton at 400 cu-ft/min, 2.5 ton at 350 cu-ft/min, 40 V-A at 24 VAC Transformer, Steel, 30 - 60 deg F Low, 40 - 70 deg F High Rise

  • Extra SEER variable speed ECM blower motor
  • Supports one and two-stage cooling units
  • Dehumidification feature in cooling
  • 24 VAC humidifier terminal and electronic air cleaner terminal
  • Certified to leak 2% or less of nominal air conditioning cu-ft/min delivered when pressurized to 1 in WC with all present air inlets, air outlets and condensate drain ports sealed
  • Tougher - flame roll-out sensors standard, adjustable heating blower off delay, factory set blower on delay, RPJ aluminized heat exchanger, stainless steel secondary heat exchanger, high temperature limit control prevents overheating, direct ignition with silicon nitride igniter
  • Quieter - operates quieter at lower heating rates, variable speed induced draft combustion blower, variable speed ECM blower motor
  • Direct vent (2-pipe), single pipe venting or ventilated combustion air
  • Innovative knobs for easy door removal and secure attachment
  • Through the casing flue pipe for counterflow or horizontal applications with accessory
  • Four position upflow/down flow/horizontal installation
  • At least 12 different venting configurations
  • Self configuring and communicating control
  • Slide out heat exchanger and blower assembly
  • Extra AFUE efficiency
  • 4.5 - 13.6 in WC inlet gas pressure

back To Top