HEIL® G9MAC0801714A Gas Furnace, 80000 Btu/hr Input BTU, 115 VAC, 1400 cu-ft/min, 1/2 hp at 300 - 1300 rev/min, 97% AFUE

Manufacturer: Carrier
Part #: HEHG9MAE0801714
Customer Part #:
Login for Availability
Login for Price
AFUE Rating      :      97 %
Amperage Rating      :      9.7 A Maximum, 12.7 A Unit
Blower Size      :      11 in Dia x 8 in W
CFM Rating      :      1400 cfm
Cabinet Dimensions      :      17-1/2 in W x 29-1/2 in D x 35 in H
Configuration      :      Multi-Position
Connection Type      :      1/2 in NPT
Frequency Rating      :      60 Hz
Fuel Type      :      Natural Gas
HP Rating      :      1/2 hp at 300 to 1300 rpm
Input BTU Rating      :      80000 Btu/hr
Material      :      Steel
Model      :      G9MAC
Number of Burners      :      4
Phase      :      1 ph
Temperature Rise      :      50 - 80 deg F Initial, 35 - 65 deg F Low, 40 - 70 deg F High
Tonnage      :      3.5 ton at 400 cfm, 4 ton at 350 cfm
Transformer Rating      :      40 VA at 24 VAC
Voltage Rating      :      115 VAC

HEIL® Gas Furnace, G9MAC Model, 80000 Btu/hr Input BTU Rating, 115 VAC, 9.7 A Maximum, 12.7 A Unit, 1400 cu-ft/min, 1/2 hp at 300 - 1300 rev/min, 97% AFUE, 1 -Phase, 60 Hz, Configuration: Multi-Position, 1/2 in NPT Connection, Natural Gas Fuel, 4 -Burner, 8 in W x 11 in Dia Blower Size, 17-1/2 in W x 35 in H x 29-1/2 in D Cabinet Dimensions, 3.5 ton at 400 cu-ft/min, 4 ton at 350 cu-ft/min, 40 V-A at 24 VAC Transformer, Steel, 50 - 80 deg F Initial, 35 - 65 deg F Low, 40 - 70 deg F High Rise

  • Extra SEER variable speed ECM blower motor
  • Supports one and two-stage cooling units
  • Dehumidification feature in cooling
  • 24 VAC humidifier terminal and electronic air cleaner terminal
  • Certified to leak 2% or less of nominal air conditioning cu-ft/min delivered when pressurized to 1 in WC with all present air inlets, air outlets and condensate drain ports sealed
  • Tougher - flame roll-out sensors standard, adjustable heating blower off delay, factory set blower on delay, stainless steel RPJ aluminized heat exchanger, stainless steel secondary heat exchanger, high temperature limit control prevents overheating, direct ignition with silicon nitride igniter
  • Quieter - operates quieter at lower heating rates, variable speed induced draft combustion blower
  • Direct vent (2-pipe) or ventilated combustion air
  • Innovative knobs for easy door removal and secure attachment
  • Through the casing flue pipe for counterflow or horizontal applications with accessory
  • Four position upflow/down flow/horizontal installation
  • At least 12 different venting configurations
  • Self configuring and communicating control
  • Slide out heat exchanger and blower assembly
  • Modulating ECM variable speed blower
  • 4.5 - 13.6 in WC inlet gas pressure