Amperage Rating | : | 150 mA |
Flow Rate | : | <20 gph |
Frequency Rating | : | 60 Hz |
Humidity Rating | : | 5 to 95% RH Non-Condensing/Non-Crystallizing |
Ignition Type | : | Intermittent Pilot |
Lockout Time | : | 15 s |
Temperature Rating | : | -40 to 50 deg F |
Voltage Rating | : | 120 VAC |
The Beckett GeniSys™ advanced burner control is a 120 VAC primary safety control. The GeniSys™ is used with a suitable cad cell flame sensor to control the oil burner motor, igniter and optional solenoid valve. It has 24 VAC thermostat terminals compatible with both mechanical and many power stealing thermostats. It can Provide interrupted or intermittent duty ignition and it has a 15 s lockout time.
Beckett® Burner Control, 120 VAC, 150 mA, 60 Hz, 15 s Lockout, -40 to 50 deg F, 5 to 95% RH Non-Condensing/Non-Crystallizing Humidity Rating, Intermittent Pilot Ignition, <20 gph
- Thermostat and boiler control compatible
- Customizable pre-time and post time
- (3) status lights for system monitoring and diagnostics
- Welded relay protection with redundant motor relays
- Limited reset and limited recycle
- Sleek, modern design
- Technician pump prime mode
- (2) communication ports for adding alarm contacts, programming display and/or future wireless communications